亚洲欧美日韩一区高清中文字幕_欧美黄色免费网址_k频道欧美成人午夜视频综合_在线欧美69v免费观看视频_成人免费观看www视频_中文字幕不卡免费视频_日本欧美一区二区三区高清_永久免费在线看

Boiler Fan >> Y8-39 ,9-38 Boiler Fan
科技創(chuàng)新 Tenchnology

Y8-39 ,9-38 Boiler Fan

Patent No.:


★ Overview

Y9-38 boiler centrifugal induced draft fan is to make industrial boilers at runtime variable condition fan can work in the high zone , in order to save energy and the development of energy efficient fans , organized by the Ministry of Machinery Industry jointly designed famous national fan industry , the National Economic Commission and the Ministry of Machinery Industry application , with high efficiency , low noise , the performance curve efficient wide area and so on.

The fan is equipped with economizer for ( preheater ) and the smoke and dust removal device 0.5 ~ 35t / h industrial boiler selection, where the inlet conditions similar performance but also suitable for those who can be selected , but the maximum inlet temperature shall not exceed 250 ℃.

Improvement of the Company 's overall style 9-38 boiler centrifugal induced draft fan , and its aerodynamic performance with the original machine the same, and the fan body , transmission, motor assembly in the same housing above the bottom of the base with a plurality of damping is flexible contact with the ground . Consumers do not need to order special foundation , placed on a solid flat floor or floor , took over power, you can use .

★ Type and Structure

A machine number

There 4,4.5,5,5.6,6.3,7.1,8,9,10,11.2,12.5,14,16 thirteen machine number ( machine number equal to the number of units multiplied by 100 mm impeller diameter ) .

2 Transmission

All gauges have a D drive mode , in which a machine number 7.1 and 8 C drive mode

Type C - motor through pulleys, belts, bearings Gearbox

D -type - motor via a coupling, transmission bearing housing

3 assembly type

3.1 fan can be made L (N) and D (S) two kinds of rotation type, direction from the motor , impeller counterclockwise (N) spin left-handed ; impeller clockwise (S) is right-handed .

3.2 the fan outlet in a horizontal position as a reference point , can be made 0 °, 45 °, 90 ° 135 °, 180 °, 225 ° six kinds of patterns.

3.3 regardless of type C or D type , fans are installed in all parts of the whole rack above the bottom of the rack is equipped with shock absorber soft contact with the ground , without a dedicated fan base .

Four major structural components

      
4.1 Impeller - by fans new and efficient theoretical design forward by the blades, front disc , rear disc and shaft plate welding components. Impeller material can be selected according to the requirements of different high-quality carbon steel, manganese steel or corrosion-resistant stainless steel . After molding machines with advanced balance static and dynamic balance calibration, so smooth and reliable operation .

      
4.2 chassis ( including the front cover ) - based on the design of the prototype steel reinforcing frame , rigidity and load carrying positive and negative pressure so that it greatly improved the performance , chassis body material is also different according to the demand of high quality carbon steel or corrosion can be corrosion of stainless steel .

      
4.3 transmission - from the main shaft , bearings , water- cooled bearing housing , coupling or pulley mechanism and other components .

★ installation , commissioning and maintenance

   
1 check - should be checked before installation whether there are internal debris blower , if so, to be clear ; steers the impeller, if there is virtually scratch phenomenon , found inadequacies must be timely adjustments intact.

   
2 Foundation - thickness not less than 300mm concrete floor surface basic level, plus put on the rack around and not less than 300mm above the surrounding floor about 100mm ( waterproof ) ; fans can carry the weight of the floor , roof .

   
3 Commissioning - damper shall be closed before starting the blower at no load condition starts to reach normal operating speed can be gradually open the valve until the rated condition. During operation should be strictly monitored current must not exceed rating. Fan running after 20 minutes should check bearing housing temperature is normal ( temperature rise shall not exceed the ambient temperature 40 ℃, surface temperature should not exceed 70 ℃).

   
4 Maintenance - fan maintenance must first shut down power ; according to the actual situation in due course replace the lubricant ( oil or grease ) ; increased vibration occurs when the fan , bearing temperature is too high , the motor current is too large body of overheating are not normal circumstances , should promptly identify the reasons for troubleshooting before running again.

★ Y9-38 Boiler Fan Performance Parameters

 

Machine number

 Transmission

 Speed

 Full pressure

 Flow

Equipped with a motor

r/min

Pa

m³/h

 Model

 Power/KW

4

D

2900

2275

3297

Y13S1-2

5.5

2334

3846

2334

4396

2294

4945

Y13S2-2

7.5

2226

5495

4.5

D

2900

2873

4694

Y160M1-2

11

2951

5477

2961

6259

2912

7042

2814

7824

5

D

2900

3550

6439

Y160M2-2

15

3648

7513

3658

8586

Y160L-2

18.5

3589

9659

3481

10733

5.6

D

2900

4452

9047

Y200L1-2

30

4570

10555

4579

12063

4511

13571

Y200L2-2

37

4364

15079

6.3

D

1450

1402

6441

Y132S-4

5.5

1441

7514

1451

8588

Y132M-4

7.5

1422

9661

1372

10735

2900

5639

12882

Y225M-2

45

5786

15029

5805

17176

Y250M-2

55

5707

19323

5521

21470

Y280S-2

75

7.1

D

1450

1784

9219

Y160M-4

11

1863

10756

1873

12292

1863

13829

Y160L-4

15

1833

15366

1794

16902

1735

18439

Y180M-4

18.5

8

D

1450

2275

13189

Y180L-4

22

2363

15387

2373

17585

2363

19783

2334

21982

Y200L-4

30

2285

24180

2206

26378

7.1

C

1600

2177

10173

Y180M-4

18.5

2265

11869

2275

13564

2265

15260

2235

16955

2186

18651

Y180L-4

22

2108

20346

8

C

1600

2765

14553

Y200L-4

30

2873

16978

2893

19404

2873

21830

Y225S-4

37

2834

24255

2775

26081

Y225M-4

45

2677

29106

 

 

Machine number

Transmission

Speed

Full pressure

Flow

Equipped with a motor

r/min

Pa

m³/h

 Model

 Power/KW

9

D

1450

2873

18778

Y225S-4

37

2991

21908

3010

25038

2991

28168

Y250M-4

55

2951

31298

2893

34427

2785

37557

10

D

1450

3550

25760

Y250M-4

55

3687

30053

3716

34346

Y280S-4

75

3687

38639

3648

42933

3569

47226

Y280M-4

90

3442

51519

11.2

D

1450

4462

36190

Y315S1-4

110

4628

42222

4658

48254

4462

54285

T315M1-4

132

4570

60317

4471

66349

T315M2-4

160

4324

72381

960

1951

23960

Y225M-6

30

2030

27954

2039

31947

2030

35941

Y280S-6

45

2000

39934

1961

43927

1892

47921

12.5

D

1450

5560

50312

Y315M2-4

160

5766

58697

5805

67082

Y355M1-4

200

5766

75468

Y355M2-4

250

5697

83853

5580

92238

Y355M3-4

315

5384

100624

960

2432

33310

Y280M-6

55

2530

38861

2540

44413

2530

49965

Y315S1-6

75

2490

55516

2441

61068

2353

66620

Y315M1-6

90

730

1402

25330

Y225M1-8

22

1461

29550

1471

33772

Y250M-8

30

1461

37994

1441

42215

1412

46437

Y280S-8

37

1363

50659

14

D

960

3049

46798

Y315S1-6

75

3167

54597

Y315M1-6

90

3187

62397

Y315M2-6

110

3167

70197

3128

77997

Y315M3-6

132

3059

85796

2961

93596

Y355M1-6

160

730

1756

35586

Y280S-8

37

1833

41517

1843

47448

Y280M-8

45

1833

53397

1814

59310

Y315S-8

55

1775

65241

Y315M1-8

75

1716

71172

16

D

960

3991

69856

Y355M1-6

160

4138

81498

4167

93141

Y355M2-6

200

4138

104784

Y355M3-6

250

4089

106427

4001

128069

3863

139712

JS-137-6

280

730

2304

53119

Y315M1-8

75

2392

61973

2402

70826

Y315M2-8

90

2392

79679

2363

88533

Y315M3-8

110

2314

97386

2235

106239

Y355M1-8

132

All Rights Reserved Hangzhou ritong blower co.,ltd copyright 2013 www.xjshgy.com