亚洲欧美日韩一区高清中文字幕_欧美黄色免费网址_k频道欧美成人午夜视频综合_在线欧美69v免费观看视频_成人免费观看www视频_中文字幕不卡免费视频_日本欧美一区二区三区高清_永久免费在线看

Low-pressure centrifugal fan >> 4-72 centrifugal fan
科技創(chuàng)新 Tenchnology

4-72 centrifugal fan

Patent No.:


★ Properties and Uses

The company produces four a 72 -type fan with good aerodynamic performance , high efficiency, smooth running characteristics .

    
Contained in the dust and hard particles should not exceed 150mg/m3, gas temperature does not exceed 8 this environment can be used as input

Gas , can be used as export gas .

★ Type

    
From the motor side of the face , the impeller rotates clockwise , called D- blower to " right" : the impeller counterclockwise rotation, called L- blower to " left".

    
Fan outlet location to the chassis of the outlet angle . No2.8-6 # factory are made ​​of a type , its angle adjustment range from 0 - 225 interval 45. No6-20 # exports made ​​from a fixed position of the three : Oy, 90v, 180, can not be adjusted .

    
The fan drive with A, B, C, D four kinds . No2.8 a 6 # with A -type transmission , No6 -12 # using C, D type transmission , No16 a 20 # using C, D type transmission .

 
★ Structure

    
4-72 type fan in Not. 8 -6 # mainly by the impeller , casing, air inlet with direct-motor and other components. In addition to a 20 # No6 with some of the above , there are transmission department.

    
1, the impeller 10 backward wing -shaped leaves , curved front plate and the plate after plate composed by static and dynamic balance correction .

    
2 , chassis made ​​of two different types , Not. 8 a 12 # casing made whole, can not open : No16 a casing made of two 20 # open along the horizontal plane carved separately bolted .

    
3 , air inlet is made whole, mounted on the fan side parallel with the axial cross-sectional shape of the curve , the gas can successfully enter the impeller, and a smaller loss .

    
4 , the transmission part of the spindle , bearing housing, bearings , pulleys or couplings components.

    
"B4 a 72 -proof centrifugal fan for the explosion environment, transport concentration below the minimum flash point formed by gas or air flammable, explosive gas mixtures are generally used for ventilation purposes. Highest transmission medium temperature does not exceed 8 0 0c, dust content and other solid impurities is not greater than 100mg/m3, diameter less than lmma B4 a 72 -proof centrifugal fan , the fan performance and structure has the following characteristics :

    
1 , fan basic types and structures , dimensions and four a 72 the same type , the user can directly use the performance table . Performance selection table is divided into ordinary and explosion-proof motors are two to choose from. Common to Ah series motor, explosion-proof as Ah B series motors.

    
2, the fan rotating parts and stationary pieces of material adjacent to the design , in addition to meet the strength stiffness requirements , but also give full consideration to the explosion-proof . To avoid grazing , to prevent sparks , fan inlet using steel manufacturing, aluminum alloy impeller . The distribution of the explosion-proof motor and ancillary electrical components with GB3836 requirements and explosion-proof product certification, its manufacturer has a corresponding explosion-proof electrical equipment production license.

    
3 , couplings and other transmission group rotating pulley transmission parts safety guard , solid structure and reliable fixation to avoid contact with rotating parts produced . To avoid the chassis , transmission group or electrostatic shield is gathering sparks in these parts has a reliable grounding device , the installation must be grounded this point , the land shall not be buried in the ground less than 2m, to ensure safety .

    
4, the fan rotating parts , assembly time has been fixed firmly , and has measures to prevent loosening . Should be checked before driving the fan inlet and impeller wheel cover imports minimum radial clearance of not less than one-sided }. 5mm, to ensure safety.

5 , in order to prevent explosive gas leakage inside the casing , the casing cover and the spindle after the junction . With aluminum seals .

★ Security Tips

    
1, when the use of explosion-proof fan inlet open to the atmosphere when directly . Inlet protection must be installed fixed grid ( or mesh ) to prevent foreign body aspiration fan inside . And the installation of additional protective devices should note that the user is responsible for two -proof fan guard can not offset occurs due to mishandling accident .

    
2, A -type explosion-proof fan must be equipped with explosion-proof motors. When users use an ordinary motor, the user should take full account of the resulting system is the possibility of an accident .

    
3 , explosion proof electric motor with attached electrical components such as junction boxes , switches, etc. shall comply with the provisions } aaea} . And have proof product certification . The manufacturers must have the appropriate explosion-proof electrical equipment production license. Wiring should standardize operations in order to avoid accidents resulting system is possible.

    
4 , the correct installation and maintenance related to the fans called wow with explosion safety , for the entire life cycle of the fan . Should seriously according to the company's " fan installation, maintenance manual " for installation, commissioning, use and maintenance.



★ 4-72 centrifugal fan performance table

 

Machine number

 

 Speed ​​rpm

 

Flow m3 / h

 

Total pressure Pa

 

 Internal Efficiency %

 Internal power kW

 Required power kW

 Equipped with a motor

2.8A

2900

1131

994

69.3

0.45

0.7

Y80S-2 1.5kW

1310

966

73.2

0.48

0.7

1480

933

75.5

0.51

0.7

1659

887

76.8

0.53

0.7

1828

835

76.9

0.55

0.8

2007

770

75.5

0.57

0.8

2177

702

73.2

0.58

0.8

2356

606

69.3

0.57

0.8

1450

566

249

69.3

0.06

0.1

Y801-4 0.55kW

655

242

73.2

0.06

0.1

740

233

75.5

0.06

0.1

830

220

76.8

0.07

0.1

914

209

76.9

0.07

0.1

1004

193

75.5

0.07

0.1

1089

176

73.2

0.07

0.1

1178

152

69.3

0.07

0.1

3.2A

2900

1688

1300

69.3

0.88

1.2

Y90L-2 2.2kW

1955

1263

73.2

0.93

1.3

2209

1220

75.5

0.99

1.3

2476

1160

76.8

1.03

1.3

2729

1091

76.9

1.07

1.4

2996

1006

75.5

1.10

1.4

3250

918

73.2

1.13

1.5

3517

792

69.3

1.11

1.5

1450

844

324

69.3

0.11

0.2

Y90S-4 1.1kW

978

315

73.2

0.12

0.2

1107

304

75.5

0.12

0.2

1238

289

76.8

0.13

0.2

1365

272

76.9

0.13

0.2

1498

251

75.5

0.14

0.2

1625

229

73.2

0.14

0.2

1758

198

69.3

0.14

0.2

3.6A

2900

2664

1578

74.2

1.56

2.0

Y100L-2 3kW

3045

1578

77.8

1.65

2.2

3405

1481

80.3

1.73

2.3

3786

1419

82.1

1.81

2.4

4146

1343

82.6

1.86

2.4

4527

1256

81.8

1.92

2.5

4887

1144

79.5

1.95

2.5

5268

989

74.3

1.94

2.5

1450

1332

393

74.2

0.20

0.3

Y90S-4 1.1kW

1522

381

77.8

0.21

0.3

1703

369

80.3

0.22

0.3

1893

353

82.1

0.23

0.3

2073

335

82.6

0.23

0.4

2263

313

81.8

0.24

0.4

2444

285

79.5

0.24

0.4

2634

247

74.3

0.24

0.4

 

 

Machine number

 

Speed ​​rpm

 

 Flow m3 / h

 

Total pressure Pa

 

Internal Efficiency %

 Internal power kW

 Required power kW

 Equipped with a motor

4A

2900

4012

2014

77.0

2.89

3.5

Y132S1-2 5.5kW

4506

1969

80.3

3.05

3.7

4973

1915

82.5

3.18

3.8

5468

1830

84.1

3.28

3.9

5962

1723

84.6

3.35

4.0

6457

1606

83.7

3.42

4.1

6924

1459

81.4

3.43

4.1

7419

1320

77.5

3.49

4.2

1450

2006

501

77.0

0.36

0.5

Y90S-4 1.1kW

2253

490

80.3

0.38

0.6

2487

476

82.5

0.40

0.6

2734

455

84.1

0.41

0.6

2981

429

84.6

0.42

0.6

3228

400

83.7

0.43

0.6

3462

363

81.4

0.43

0.6

3709

329

77.5

0.44

0.7

4.5A

2900

5712

2554

77.0

5.21

6.0

Y132S2 7.5kW

6416

2497

80.3

5.49

6.3

7081

2428

82.5

5.74

6.7

7785

2320

84.1

5.92

6.8

8489

2184

84.6

6.04

7.0

9194

2036

83.7

6.17

7.1

9859

1849

81.4

6.17

7.1

10562

1673

77.5

6.30

7.2

1450

2856

634

77.0

0.65

0.9

Y90S-4 1.1kW

3208

620

80.3

0.69

1.0

3540

603

82.5

0.72

1.0

3893

577

84.1

0.74

1.0

4245

548

84.6

0.76

1.1

4597

506

83.7

0.77

1.1

4929

460

81.4

0.77

1.1

5281

416

77.5

0.79

1.1

5A

2900

7728

3187

77.6

8.72

10.0

Y160M2-2 15kW

8855

3145

81.8

9.35

10.8

9928

3074

84.7

9.90

11.4

11054

2962

86.0

10.47

12.0

12128

2729

86.1

10.82

12.4

12355

2567

84.6

11.07

12.7

14328

2335

82.1

11.22

12.9

15455

2019

77.6

11.09

12.8

1450

3864

790

77.6

1.09

1.4

Y100L1-4 2.2kW

4427

780

81.8

1.17

1.5

4964

762

84.7

1.20

1.6

5527

735

86.0

1.30

1.7

6064

693

86.1

1.35

1.8

6628

637

84.6

1.38

1.8

7164

580

82.1

1.40

1.8

7728

502

77.6

1.39

1.8

All Rights Reserved Hangzhou ritong blower co.,ltd copyright 2013 www.xjshgy.com

Hot Topics:Axial fans and centrifugal fans distinction Several common fault handling centrifugal fan Main Products: axial fans | centrifugal fans Power By CNB-YOPIN